UC-1.6

From Archivematica
Revision as of 17:13, 3 September 2009 by Evelyn McLellan (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Main Page > Requirements > OAIS Use Cases > UC-1 Ingest > UC-1.6 Transfer of Descriptive Information to Data Management


UC-1.6 Transfer of Descriptive Information to Data Management[edit]

Summary
Number UC-1.6
Name Transfer of Descriptive Information to Data Management
Context UC-1 Ingest
Sub-Use Cases None
Overview Coordinate Updates adds storage identification information to the Descriptive Information and submits Descriptive Information to Data Management>Receive Database Updates
Actors
  • Coordinate Updates
  • Generate Descriptive Information
  • Data Management>Receive Database Updates
Description
Preconditions
Trigger
  • Generate Descriptive Information sends Descriptive Information to Coordinate Updates (Step 4 UC-1.4)
  • If AIP is not already in Archival Storage, Coordinate Updates receives storage confirmation (including storage identification information) from Archival Storage>Receive Data (Step 4 UC-1.5)
Successful outcome Coordinate Updates receives a database update response from Data Management>Receive Database Updates
Steps
  1. Coordinate Updates receives Descriptive Information from Generate Descriptive Information (OAIS Figure 4-2:Functions of Ingest Page 4-5)
  2. Coordinate Updates adds storage identification information to the Descriptive Information (OAIS Page 4-6)
  3. Coordinate Updates submits Descriptive Information to Data Management>Receive Database Updates along with a database update request (OAIS Page 4-6)
  4. Coordinate Updates receives a database update response from Data Management>Receive Database Updates (OAIS Page 4-6)
Exceptions
  • If the AIP is already in Archival Storage and the SIP contains the storage identification information, then Step 2 will not be necessary.
Documentation
Citations OAIS
  • Page 4-6 "The Coordinate Updates function is responsible for transferring the AIPs to Archival Storage and the Descriptive Information to Data Management. ... The Coordinate Updates function...incorporates the storage identification information into the Descriptive Information for the AIP and transfers it to the Data Management entity along with a database update request. In return, Data Management provides a database update response indicating the status of the update. Data Management updates may take place without a corresponding Archival Storage transfer when the SIP contains Descriptive Information for an AIP already in Archival Storage."
Diagrams
Notes
  • What is the nature of the response from Data Management>Receive Database Updates?
  • If the AIP is not already in Archival Storage, both triggers must be fulfilled because Coordinate Updates incorporates the storage identification information into the Descriptive Information.